ElectroStop by GPT

ElectroStop by GPT
0.00৳
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Description
 
The Industry’s Best Dual O-Ring Seal
The ElectroStop®  monolithic isolation fittings manufactured by GPT will serve as a positive, leak-proof, block against the flow of electric current in all piping systems. When you bury the ElectroStop® isolation joint you also bury maintenance costs; an especially important feature for system operators and engineers.
 
Eliminates Short Circuits
Bolts, sleeves and washers - the major source of short circuits in most isolation assemblies - are eliminated with the ElectroStop® isolation joint. Each joint is electrically tested during production to assure integrity, performance, isolating properties.
 
Eliminates Field Assembly
The ElectroStop® isolation joint is completely factory assembled and tested.  There are no flanges, gaskets, nuts, bolts, sleeves or washers to handle and consequently no fluid leaks due to improper 
field assembly.
 
Is Coated Both Internally and Externally
A two-part bonded epoxy is sprayed to a thickness of .016” -.024” (.40 to .60mm) to within 2” (50.8mm) of each weld end. Each joint is tested for coating thickness uniformity and for holidays.
 
Is 100% Hydrostatically Tested
All ElectroStop®  fittings undergo hydrostatic pressure tests at 1.5 times rated operating pressure in accordance with ASME B31.3 standards.  Testing is normally conducted for 30 minutes for joints up to 6” and 60 minutes for 8” to 24” joints but can be tested per customer specifications. A pneumatic test is held at 87 psi for 10 minutes.
 
Is Completely Weld Inspected
All ElectroStop®  fittings undergo a weld inspection with combinations of  ultrasonic (UT) and magnetic partical (MT) on all welds. In addition, X-ray tests can be conducted upon request. 
Manufactured under an ISO 9001:2008 Quality Management System.

 

Benefits

  • Eliminates short circuits.
  • Eliminated field assembly.
  • Eliminates maintenance.
  • Is less expensive.
  • Is coated both internally and externally.
  • Is 100% electrically tested.
  • Is completely weld inspected.
  • Is manufactured in accordance with ISO9001:2000 specifications.
  • 100% butt weld construction
     

Sizes

  • Available in any diameter.
  • Available in any ANSI Class & Stocked in ANSI Classes 150#, 300-400# and 600#.
     

 

 

Warranty

All products are warranted against failure caused by manufacturing defects for a period of one year. Any product found to be so defective and returned within one year from date of shipment will be replaced without charge. The above warranty is made in lieu of, and we disclaim, any and all other warranties, expressed or implied, including the warranties of merchantability and fitness for a particular purpose, and buyer agrees to accept the products without any such warranties. We hereby disclaim any obligation or liability for consequential damages, labor costs or any other claims or liabilities of any kind whatsoever.

Installation

THE ELECTROSTOP™ WELD-IN MONOLITHIC ISOLATION FITTING INSTALLATION GUIDE

The ElectroStop™ is a complete factory assembled and tested monolithic isolation fitting which will serve as a leak proof, long lasting block against the flow of electrical current in steel piping systems. Care should be used during the handling and installation process so as not to damage the fitting.

Only two (2) welds are required for installation.

The ElectroStop™ may be installed either above grade or buried below grade.

Note: WHEN INSTALLING IN A VERTICAL POSITION ABOVE GRADE, THE WELDED END OF THE COLLAR (HUB) SHOULD FACE UP.

The end filled with the epoxy fill (opposite end of the welded collar of hub) can have a concave area and possibly retain moisture and can be sensitive to ultra violet light exposure.

THE SUGGESTIONS BELOW SHOULD NOT PRECLUDE FOLLOWING OF ALL COMPANY, LOCAL, STATE, OR FEDERAL CODES AND/OR SAFETY REQUIREMENTS AND/OR REGULATIONS. DESIGN CONCERNS, INCLUDING ELECTRICAL SAFETY PRECAUTIONS, GROUNDING, MECHANICAL STRESSES, ETC. SHOULD BE ADDRESSED PRIOR TO USE OR INSTALLATION. ALWAYS WEAR PROPER SAFETY EQUIPMENT FOR PERSONAL PROTECTION. CONSULT WITH YOUR COMPANY.

The ElectroStop™ fitting should be installed just like any other weld-in fitting or piece of pipe with the only exceptions being:

  • The temperature of the collar (hub) should not exceed 212 degrees Fahrenheit (100 degrees Celsius).
  • Piping being attached to the ElectroStop™ must be properly aligned so as not to put undo mechanical stresses on the ElectroStop™.
     

The pipe pups on the ElectroStop™ are intended to act somewhat as a heat sink and should not be shortened. If the fitting is too long for the installation location, cut the needed length out of the existing piping, not the ElectroStop®.

During the welding operation a temperature sensor such as a thermometer or thermocouple should be secured to the collar (hub) of the ElectroStop™. As a precautionary procedure, wet rags or other cooling methods are sometimes used to reduce heat at the collar (hub) area.

COATING

After the welding operation is completed, The ElectroStop™ fitting and welds should be prepared for your corrosion protection coating or tape just like any other bare or shop coated fitting or piece of pipe.

SUPPORT AND BACKFILLING

Care should be used to assure uniform support and compaction around the entire ElectroStop™ fitting. Undo mechanical stresses caused by improper support or backfilling could cause damage to the ElectroStop™ that could result in leakage.

TESTING AND CERTIFICATION

All ElectroStop™ fittings undergo a weld inspection with combinations of ultrasonic (UT), magnetic particle (MT) and dye penetrant (LT) on all welds. X-Ray tests are preformed upon request.

We certify that each standard order ElectroStop™ will be factory tested at 1-1/2 times the rated operating pressure for the amount of time listed below and in accordance to the latest ANSI Standards.

 

Pipe SizeHydrostatic Minimum Test Time
2"-4"30 minutes
8"-24"60 minutes

 

After completion of the hydrostatic tests, The ElectroStop™ are electrically tested to assure an electrical resistance of 25 Mohms (wet or dry conditions @ 20( C) @ 1kv D.C. and a minimum breakdown voltage of 5kv @ 50 hz for 1 minute.

Control over all stages of production is ensured by close adhearance to an in-place and ongoing ISO 9001 Quality Assurance Program which is constantly monitored and subject to periodic outside audit. A qualified inspector witnesses all tests.