Part No.

Description

TL1500

Test Leads with Alligator Clips
Cat IV 1000 V (1500V Max).Supplied with meter.

FP700

Replacement Fuse, 2A/1500V. Pack of two.

TA-1A

Temperature adapter, K-type thermocouple.

CT235A

1000A Amp Clamp Accessory Current Transformer Probe
 

Converts high AC or DC current to a low level millivolt signal for input directly into a test instrument. Can be used with standard DMMs, recorders, digital or analog meters, data loggers/DAS, oscilloscopes, or other test and measurement instruments.

Maximum current

1000A, AC or DC

Division Ratio

1000:1

Output to Meter

200 A: 1A at jaws = 1 mV to meter
1000 A: 1A at jaws = 1 mV to meter

Dimensions

55 x 220 x 30 mm (2.2" x 8.6" x 1.2")

Weight

320 g (0.7 lb)

Max Conductor Size

31 mm (1.2")

Lead Length

1.5 m (59")

Power

9V battery, NEDA 1604, JIS 006P, IEC 6F22

Battery Life

50 hours (alkaline)

Meter Input Impedance

10 k Ohms min, 100 pF max

Overload Protection

700A for 10 min and 20 min Off
300 Vac on uninsulated conductors

CT237A

200A Amp Clamp Accessory Current Transformer Probe
 

Converts high AC or DC current to a low level millivolt signal for input directly into a test instrument. Can be used with standard DMMs, recorders, digital or analog meters, data loggers/DAS, oscilloscopes, or other test and measurement instruments.

Current Ranges

20A, 200A, AC or DC

Division Ratio

1000:1

Output to Meter

20A: 1A at jaws = 10 mV to meter
200A: 1A DC at jaws = 1 mV to meter

Dimensions

55 x 210 x 30 mm (2.2" x 8.3" x 1.2")

Weight

290 g (0.64 lb)

Max Conductor Size

19 mm (0.75")

Lead Length

1.5 m (59")

Power

9V battery, NEDA 1604, JIS 006P, IEC 6F22

Battery Life

50 hours (alkaline)

Meter Input Impedance

10 k Ohms min, 100 pF max

Overload Protection

700A for 10 min and 20 min Off.
300 Vac on uninsulated conductors.

CT238A

20A Amp Clamp Accessory Current Transformer Probe
 

Converts high AC or DC current to a low level millivolt signal for input directly into a test instrument. Can be used with standard DMMs, recorders, digital or analog meters, data loggers/DAS, oscilloscopes, or other test and measurement instruments.

Current Ranges

20A, AC or DC

Division Ratio

10:1

Output to Meter

1A at jaws = 100 mV  to meter

Dimensions

55 x 210 x 30 mm (2.2" x 8.3" x 1.2")

Weight

290 g (0.64 lb)

Max Conductor Size

19 mm (0.75")

Lead Length

1.5 m (59")

Power

9V battery, NEDA 1604, JIS 006P, IEC 6F22

Battery Life

30 hours (alkaline)

Meter Input Impedance

10 k Ohms min, 100 pF max

Overload Protection

500A, 300 Vac on uninsulated conductors

VC221B
Padded Vinyl Case
Fits meter & holster.


 

DC205C
Deluxe Hard-Shell Carry Case

DC207C
Large Deluxe Hard-Shell Carry Case
With extra space for accessories

HV231-10A

Handheld High-Voltage Probe
High voltage probe for AC or DC extends voltage measuring to 40 kV. Use with standard multimeters with 10 MΩ input impedance.

Dimensions

340 mm (13.3") length, 30 mm (1") handle,
75 mm (3") guard.

Weight

218 g (7.7 oz)

Cable Length

1 m (39")

Input Resistance

1000 MΩ

Maximum Voltage

40 kV peak, 28 kV AC RMS

Accuracy

DC (1 kV to 20 kV): ± 1 %
DC (20 kV to 40 kV): ± 2 %
AC (1 kV to 20 kV) (50/60 Hz): ± 5 %